feat(instances): ISO eject/mount with boot-order switch and hybrid reboot
Some checks failed
Deploy to Production / Trigger production update (push) Has been cancelled
Backend Tests / pytest (Python 3.12) (push) Has been cancelled

- Images: show real ISO files already on the node storage (incl. those
  present before the node joined the panel) via existing node/isos endpoint
- ISO dialog: rename "detach" to "Eject", show current image inside the
  select (drop overflowing side text), add "boot from disk" checkbox
- Backend: on eject, put disk first in boot order; on mount, optional
  "boot from this ISO" puts CD-ROM first
- Reboot to apply the new boot order via hybrid restart: graceful ACPI
  shutdown with forceStop fallback, then start (fixes guest-ping timeout
  on freshly installed OS without QEMU Guest Agent)
- Update iso_next_steps hint to reflect the automated flow
This commit is contained in:
markmorado
2026-07-24 23:00:32 +05:00
parent aa100b49c1
commit b7c3a6ed35
8 changed files with 311 additions and 37 deletions

View File

@@ -1,4 +1,5 @@
from typing import List, Dict, Optional, Union, Any
import re
import time
import urllib3
from loguru import logger
@@ -40,6 +41,46 @@ class VmMixin:
logger.error(f"Ошибка перезапуска VM {vmid} на {node}: {e}")
return None
def _wait_vm_stopped(self, node: str, vmid: int, timeout: int) -> bool:
"""Опрашивать статус ВМ, пока не 'stopped' или не выйдет timeout секунд."""
deadline = time.time() + timeout
while time.time() < deadline:
st = self.get_vm_status(node, vmid) or {}
if st.get('status') == 'stopped':
return True
time.sleep(1)
return False
def hybrid_restart_vm(self, node: str, vmid: int,
graceful_timeout: int = 20) -> bool:
"""Перезапуск «мягко, при таймауте — жёстко», затем start.
status/shutdown с forceStop=1 сначала шлёт ACPI-выключение, а если гость
не ответил за graceful_timeout секунд — Proxmox сам убивает процесс QEMU.
Это покрывает и живую ОС (корректное выключение), и свежий установщик без
ACPI/QEMU Guest Agent (где обычный reboot виснет на guest-ping). Нужен для
применения нового boot order. Возвращает True, если ВМ снова запущена.
"""
if not self.proxmox:
return False
try:
self.proxmox.nodes(node).qemu(vmid).status.shutdown.post(
timeout=graceful_timeout, forceStop=1)
# Ждём с запасом сверх graceful_timeout (форс-стоп внутри shutdown).
if not self._wait_vm_stopped(node, vmid, graceful_timeout + 20):
# Подстраховка: shutdown завис — бьём по процессу напрямую.
logger.warning(f"VM {vmid}: shutdown не завершился, принудительный stop")
self.proxmox.nodes(node).qemu(vmid).status.stop.post()
if not self._wait_vm_stopped(node, vmid, 15):
logger.error(f"VM {vmid} не остановилась — старт отменён")
return False
upid = self.proxmox.nodes(node).qemu(vmid).status.start.post()
logger.info(f"VM {vmid} на {node}: гибридный перезапуск выполнен, UPID: {upid}")
return isinstance(upid, str)
except Exception as e:
logger.error(f"Ошибка гибридного перезапуска VM {vmid} на {node}: {e}")
return False
def shutdown_vm(self, node: str, vmid: int, timeout: int = 60) -> Optional[str]:
"""Корректно выключить VM (ACPI). Возвращает UPID задачи."""
if not self.proxmox:
@@ -204,6 +245,81 @@ class VmMixin:
logger.error(f"Ошибка отключения ISO у VM {vmid}: {e}")
return False
def _ordered_boot_disks(self, cfg: Dict,
exclude_device: Optional[str] = None) -> List[str]:
"""Загрузочные диски ВМ (не CD-ROM, не пустые) в порядке текущего boot.
Порядок между дисками берём из текущего boot=order=...; недостающие
добавляем в конец. exclude_device исключается принудительно. efidisk/
tpmstate не проходят regex дисковых устройств, поэтому не попадают.
"""
disk_re = re.compile(r'^(?:scsi|virtio|sata|ide)\d+$')
disks: List[str] = []
for key, val in cfg.items():
if not disk_re.match(key):
continue
if exclude_device and key == exclude_device:
continue
if not isinstance(val, str) or not val:
continue
if 'media=cdrom' in val or val.startswith('none'):
continue
disks.append(key)
ordered: List[str] = []
m = re.search(r'order=([^,]+)', str(cfg.get('boot') or ''))
if m:
for dev in m.group(1).split(';'):
if dev in disks and dev not in ordered:
ordered.append(dev)
for dev in disks:
if dev not in ordered:
ordered.append(dev)
return ordered
def set_boot_disk_first(self, node: str, vmid: int,
exclude_device: Optional[str] = None) -> bool:
"""Поставить дисковые устройства первыми в порядке загрузки, исключив CD-ROM.
Используется после установки ОС: извлекли ISO — грузимся с диска.
exclude_device (например отключаемый ide2) исключается из рассмотрения.
"""
if not self.proxmox:
return False
try:
cfg = self.proxmox.nodes(node).qemu(vmid).config.get() or {}
ordered = self._ordered_boot_disks(cfg, exclude_device=exclude_device)
if not ordered:
logger.warning(f"VM {vmid}: не найден загрузочный диск для boot order")
return False
self.proxmox.nodes(node).qemu(vmid).config.put(boot=f"order={';'.join(ordered)}")
logger.info(f"VM {vmid} на {node}: порядок загрузки → диск ({';'.join(ordered)})")
return True
except Exception as e:
logger.error(f"Ошибка установки boot order (диск) у VM {vmid}: {e}")
return False
def set_boot_iso_first(self, node: str, vmid: int,
iso_device: str = 'ide2') -> bool:
"""Поставить CD-ROM (ISO) первым в порядке загрузки, диски — следом.
Используется при монтировании ISO на работающую ВМ, когда нужно
загрузиться именно с образа (live-CD, восстановление, переустановка).
iso_device — привод с ISO (ide2 по умолчанию).
"""
if not self.proxmox:
return False
try:
cfg = self.proxmox.nodes(node).qemu(vmid).config.get() or {}
disks = self._ordered_boot_disks(cfg) # CD-ROM сюда не попадёт
order = [iso_device] + [d for d in disks if d != iso_device]
self.proxmox.nodes(node).qemu(vmid).config.put(boot=f"order={';'.join(order)}")
logger.info(f"VM {vmid} на {node}: порядок загрузки → ISO ({';'.join(order)})")
return True
except Exception as e:
logger.error(f"Ошибка установки boot order (ISO) у VM {vmid}: {e}")
return False
def force_stop_vm(self, node: str, vmid: int) -> bool:
"""Принудительно остановить ВМ (через SSH - аналог kill -9)"""